All projects
Lausanne · VD2024
Residential building Lausanne — Geothermal + 80 solar panels
Property management, 18-unit 1970s building. 4 geothermal probes (220 m), 80 panels at 410 Wp, 50 kWh battery.
Context
The client came to us with an advanced brief: rising energy bills, end-of-life equipment, ambition for maximum autonomy. Our role: scope it technically, size it precisely, and coordinate everything.
The challenge
Combining two technologies (e.g. HP + PV) in an existing building demands attention: cross-sizing, load profiling, quality of grid connection. Without a system approach, two solutions can interfere with each other.
The deployed solution
- Geothermal heat pump with vertical probes.
- Photovoltaic installation optimized for self-consumption.
Measured outcomes
After 12 months of monitoring, the figures matched the simulation within ±5%. Exactly what the client expected: no empty promises, measured data.
The project was carried out with tenants in place without any disruption. Charges reduced by 35%.
Similar project?
Request a tailored study for your building.